Products

  • 1384 series, network, TS bus

    Product description

    To control electric locking systems in doors along escape routes; certified.

    Escape door control module
    • Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
    • Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
    • Emergency button sign (arrow pointing downwards)
    • Multi-tone signal and tampering contact
    • Adjustable time period for max. continuous release, temporary unlocking, pre-alarm, alarm interval, guidance signal
    • Monitoring of time door is open in the case of temporary unlocking
    • With an input featuring adjustable parameters for:
    • Control of locking and unlocking, temporary unlocking, alarm acknowledgement via a potential-free contact in operating devices, such as card readers and keypad units, or
    • Temporary release using an access control system, or
    • Emergency release via fire alarm system, or
    • Priority locking via burglar alarm system
    • With a relay output featuring adjustable parameters for:
    • Door locked/unlocked, or
    • Collective alarm, or
    • Activation of electric strike/motorized lock/door automatics
    • Connections:
    • SYSCON-4: power supply
    • SYSCON-5: operating unit
    • Plug-in screw terminals
    Key switch module
    • For locking/unlocking, temporary unlocking, alarm resetting
    • Sabotage switch
    • With Euro profile half cylinder, including 3 keys
    • Cover which matches the corresponding switch fitting
    Scope of delivery
    • 1 escape door control module
    • 1 key switch module
    • 1 frame
    • 1 operating manual
    Note
    • Jung AS500 - alpine white
  • 1384 series, stand alone

    Product description

    To control electric locking systems in doors along escape routes; certified.

    Escape door control module
    • Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
    • Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
    • Emergency button sign (arrow pointing downwards)
    • Multi-tone signal and tampering contact
    • Adjustable time period for max. continuous release, temporary unlocking, pre-alarm, alarm interval, guidance signal
    • Monitoring of time door is open in the case of temporary unlocking
    • With an input featuring adjustable parameters for:
    • Control of locking and unlocking, temporary unlocking, alarm acknowledgement via a potential-free contact in operating devices, such as card readers and keypad units, or
    • Temporary release using an access control system, or
    • Emergency release via fire alarm system, or
    • Priority locking via burglar alarm system
    • With a relay output featuring adjustable parameters for:
    • Door locked/unlocked, or
    • Collective alarm, or
    • Activation of electric strike/motorized lock/door automatics
    • Connections:
    • SYSCON-4: power supply
    • SYSCON-5: operating unit
    • Plug-in screw terminals
    Key switch module
    • For locking/unlocking, temporary unlocking, alarm resetting
    • Sabotage switch
    • With Euro profile half cylinder, including 3 keys
    • Cover which matches the corresponding switch fitting
  • 1385 series, network, TS bus

    Product description

    To control electric locking systems in doors along escape routes; certified.

    Escape door control module
    • Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
    • Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
    • Emergency button sign (arrow pointing downwards)
    • Multi-tone signal and tampering contact
    • Adjustable time period for max. continuous release, delay in continuous release, temporary unlocking, pre-alarm, alarm interval, guidance signal
    • Monitoring of time door is open in the case of temporary unlocking
    • With an input featuring adjustable parameters for:
    • Control of locking and unlocking, temporary unlocking, alarm acknowledgement via a potential-free contact in operating devices, such as card readers and keypad units, or
    • Temporary release using an access control system, or
    • Emergency release via fire alarm system, or
    • Priority locking via burglar alarm system, or
    • Unlocking via timer and many other systems
    • With a relay output featuring adjustable parameters for:
    • Door locked/unlocked, or
    • Door open/closed, or
    • Collective alarm, or
    • Individual alarm, or
    • Activation of electric strike/motorized lock/door automatics/arrestor system
    • TS bus interface for parameterisation using software (FT Manager) and networks for parallel operation of visual display software, panel and OPC server
    • Connections:
    • SYSCON-4: power supply
    • SYSCON-5: operating unit
    • Plug-in screw terminals
    Key switch module
    • For locking/unlocking, temporary unlocking, alarm resetting
    • Sabotage switch
    • With Euro profile half cylinder, including 3 keys
    • Cover which matches the corresponding switch fitting
    Scope of delivery
    • 1 escape door control module
    • 1 key switch module
    • 1 frame
    • 1 operating manual
    Note
    • Gira E2 - gloss pure white
  • 1385 series, stand alone

    Product description

    To control electric locking systems in doors along escape routes; certified.

    Escape door control module
    • Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
    • Integrated visual door status indicator with high-performance LEDs (green / red / yellow) signalling unlocked / locked / alarm status
    • Emergency button sign (arrow pointing downwards)
    • Multi-tone signal and tampering contact
    • Adjustable time period for max. continuous release, delay in continuous release, temporary unlocking, pre-alarm, alarm interval, guidance signal
    • Monitoring of time door is open in the case of temporary unlocking
    • With an input featuring adjustable parameters for:
    • Control of locking and unlocking, temporary unlocking, alarm acknowledgement via a potential-free contact in operating devices, such as card readers and keypad units, or
    • Temporary release using an access control system, or
    • Emergency release via fire alarm system, or
    • Priority locking via burglar alarm system, or
    • Unlocking via timer and many other systems
    • With a relay output featuring adjustable parameters for:
    • Door locked/unlocked, or
    • Door open/closed, or
    • Collective alarm, or
    • Individual alarm, or
    • Activation of electric strike/motorized lock/door automatics/arrestor system
    • TS bus interface for parameterisation using software (FT Manager) and networks for parallel operation of visual display software, panel and OPC server
    • Connections:
    • SYSCON-4: power supply
    • SYSCON-5: operating unit
    • Plug-in screw terminals
    Key switch module
    • For locking/unlocking, temporary unlocking, alarm resetting
    • Sabotage switch
    • With Euro profile half cylinder, including 3 keys
    • Cover which matches the corresponding switch fitting
4 / 4