Connect Door Reader Modules to your Incedo Business system and configure them quickly and error-free.

Door Reader Modules are a bridge between your ASSA ABLOY Incedo access control system and hardwired doors with readers. A single Door Reader Module may connect up to two door readers to your system.

The ASSA ABLOY reader range includes multiple options in Mullion, Standard and PIN & Prox styles. Each model is also available with optional Bluetooth Low Energy capability.

Colour markings on Incedo Door Reader Modules match the outputs from ASSA ABLOY readers, saving your installer valuable time.

The Door Reader Module supplies power for both 5V and 12V door readers. Individual lock outputs support Fail Safe and Fail Secure locks. Status LEDs provide instant visual engineering feedback to installers and maintenance staff.

Get in touch with a Incedo expert

1 of 4

Colour Black
Dimensions (d-w-h) 16.6cm x 7.4cm x 3.5cm (EAC-DM5)
18.6cm x 9.9cm x 5.7cm (EAC-DP5 )
Approximate product weight 273g (EAC-DM5)
280g (EAC-DP5)
Material ABS Plastic
Electrical specifications
Input voltage 12 -15V DC
Power requirements 37mA @12VDC (0.44Watt)
Power input protection Reverse polarity, over-voltage and over-current protection
Relay Power Requirements An additional ~0.4 W per Relay used
Other specifications
Buffered transfers 100,000
Credential compatibility
RFID Technology CSN Read capability from various Tag types: iCLASSS(R)/ISO 14443B; MIFARE Classic(R)/MIFARE(R); DESFire(R) EV1; HID PROX/EM410x ASSA ABLOY Card and Token credentials
Environmental specifications 
Operating temperature -25° to +60°C [-13° to +140° F] 
Storage temperature -40° to +80°C [-40° to +176° F] 
Operating humidity 0 to 95% relative humidity non-condensing (at +40° C / +104° F)
Environmental rating IP20
Certifications
CE RCM (EU) Yes

 

  • EAC-DP5 Quick Start Guide(PDF, 331 KB)
  • EAC-DM5 and EAC-DP5 Data sheet(PDF, 585 KB)
  • EAC-DM5 Quick Start Guide(PDF, 341 KB)
DescriptionPart numberBar code
Reader Module on IPS backplateEAC-DM58592721280844
Reader Module in Plastic HousingEAC-DP58592721280882